AZtec Sample Coolers are designed to handle high-temperature & high-pressure steam or liquids found in Thermal Power Plants and Captive Power Plants (CPP). It functions well with boiler feed water, saturated steam, superheated steam and more….. It can be used for cooling of hydrocarbon liquids and fuel oil. Applications for high-temperature and high-pressure liquids found in various process industries are within our purview. AZtec sample coolers are designed to meet international standards ASME PTC 19.11, ASME Sec- VIII; Div-1 and EPRI. To accommodate wide range of industrial applications, we provide shell and tube, double helical and single helical coil type designs. Our coolers are designed to provide excellent performance with low maintenance. AZtec possesses technological know-how to design and manufacture sample coolers in accordance with customer's specifications to meet their specific sampling requirement.
Specification | Details |
---|---|
Process Connection Options | ¼” OD and 3/8” OD |
Coil Material Options | Carbon Steel / Copper Nickel / SS304 / SS316 / 316L / Inconel 625 |
Shell Material Options | Carbon Steel / Copper Nickel / SS304 / SS316 / 316L / Inconel 625 |
Sample Inlet Pressure | Upto 250 Bar(g) (Standard) and upto 400 Bar(g) (Optional) |
Sample Inlet Temperature | Upto 540 °C (Standard) and upto 660 °C (Optional) |
Shell Inlet Pressure | Upto 10 Bar(g) (Standard) and upto 31 Bar(g) (Optional) |
Shell Inlet Temperature | Upto 80 °C (Standard) and upto 343 °C (Optional) |
Flange Options | Slip-on Raised Face, Weld Neck (Standard), Ring Type Joint (RTJ) (Optional) |
Coil Materials (Special Requirement) | NACE Material / Exotic Alloys for corrosion resistance applications (Optional) |
Post Weld Heat Treatment (PWHT) | Offered on request |
Solution Annealing After Cooling Solution | Offered on request |